Incubated Shakers / Orbital Shaking Incubators

We are Manufacturer, Supplier, Exporter of Incubator Shakers, Shaking Incubators, Orbital Shaking Incubators, Incubated Shakers, Temperature Controlled Shaker Incubators, Stackable Shaking Incubators, Floor Incubator Shakers. Our setup is situated in Pune, Maharashtra, India.

Incubator Shakers :
An incubator shaker can be viewed a mix of an incubator and a shaker. It has an potential to shake while preserving ideal conditions for incubating microbes or DNA replications. This equipment is very beneficial since, in order for a cell to grow, it needs oxygen and vitamins that require shaking so that they can be allotted evenly around the culture.e dissolved oxygen attention will flip out to be zero.

Stackable Incubator Shaker: Model - Manthan IS42 (Can be stacked up to 3 units)

Stackable Incubator Shaker: Model - Manthan IS42
Incubated Shakers Incubated Shakers Incubated Shakers Incubated Shakers Incubated Shakers
Capacity 42 clamps of 250 ml or 25 clamps of 500 ml or 15 clamps of 1000 ml or 09 clamps of 2000 ml or mix capacity as per user requirement (select any one). Threaded holes to hold assorted clamps
Platform Size 700mm × 550mm
Working Chamber D × W × H = 685mm × 795mm × 530mm
Overall Dimension D × W × H = 805mm × 1254mm × 730mm approx.
Shaking Orbit 12.5mm or 25mm or 50mm (customized orbit available on request)
Speed 500 RPM @ 12.5 mm Orbital Stroke
400 RPM @ 25 mm Orbital Stroke
300 RPM @ 50 mm Orbital Stroke
Control System Microprocessor-based control system or HMI PLC with data logging facility provided (optional)
Temp Range 15°C below ambient to 60°C (Min temp 10°C). RPM accuracy: ±3 RPM or better
Temp Accuracy ±0.2°C or better
Temp Uniformity ±1°C or better
RPM Accuracy ±3 RPM or better
Alarm High temperature & low temperature alarm provided
Mechanism Heavy-duty long-lasting mechanism
Illumination Inspection lamp provided. Illumination unit for photosynthesis can be provided (optional)
Power Required 230V, 50 Hz single phase, 15 amp stabilized



Floor Mounted Incubator Shaker: Model - Manthan IS46

HSN CODE 84198990
Capacity 09 clamps of 2000 ml. OR 46 clamps of 250 ml flasks OR 32 clamps of 500 ml. OR 16 clamps of 1000 ml. OR 05 clamps of 5000 ml. & 04 clamps of 500 ml.
OR mix capacity 05 clamps of 2000 ml. & 15 clamps of 250 ml. (select one)
Threaded holes can be made to hold assorted clamps.
Platform Size 585 × 635 mm approx.
Working Chamber D × W × H = 754 × 680 × 730 mm approx.
Overall Dimension D × W × H = 1206 × 852 × 1630 mm approx.
Shaking Orbit 50 mm fixed OR 25 mm fixed (select one)
Speed 50 – 250 rpm for flasks 2000 ml. & below
50 – 180 rpm for 5000 ml.
RPM Accuracy ± 3 rpm or better
Control System HMI PLC with data logging facility provided (optional)
Data Acquisition 21 CFR Part 11 compliant software for data acquisition or direct print-out facility via printer port. (Optional)
Temp. Range 15°C below ambient to 60°C
(Minimum temperature 10°C)
Temp. Accuracy ± 0.2°C from 16°C to 60°C
± 1°C from 10°C to 15°C
Temp. Uniformity ± 1°C
Illumination Inspection lamp provided
Tray Can be used for petri plates up to 1000 ml
Refrigeration System Patent pending, innovative refrigeration system for precise temperature accuracy and low maintenance
Alarm Temperature overshoot & undershoot alarm provided
Mechanism Heavy-duty, long-lasting mechanism
Power Required 230 V, 50 Hz, Single Phase, 15 Amps Stabilized



Stackable Incubator Shaker: Model - Manthan IS25 (Can be stacked up to 2 units)

Capacity 25 clamps of 250 ml flasks OR 16 clamps of 500 ml OR 09 clamps of 1000 ml (select any one)
Threaded holes to hold assorted clamps.
Platform Size 21.2" × 18.1"
Working Chamber D × W × H = 24.2" × 20.6" × 21.6"
Overall Dimension D × W × H = 31.6" × 38.7" × 26.3"
Shaking Orbit 12.5 mm OR 25 mm OR 50 mm (customized orbit available on request)
Speed 500 RPM @ 12.5 mm Orbital Stroke
400 RPM @ 25 mm Orbital Stroke
300 RPM @ 50 mm Orbital Stroke
Control System Microprocessor-based control system or HMI PLC with data logging facility (optional)
Temp. Range 20°C below ambient to 60°C (Minimum temperature 5°C)
Temp. Accuracy ± 0.2°C or better
Temp. Uniformity ± 1°C or better
Alarm Temperature overshoot & undershoot alarm provided
Mechanism Heavy-duty, long-lasting mechanism with both orbital & linear motion
Illumination Inspection lamp provided. Illumination unit for photosynthesis can be provided (optional)
Power Required 230 V, 50 Hz, single phase, 15 amp stabilized



Stackable Incubator Shaker: Model - Manthan IS15 (Can be stacked up to 2 units)

Capacity 18 clamps of 250 ml flasks OR 09 clamps of 500 ml flasks OR 05 clamps of 1000 ml OR 01 clamp of 5000 ml (select any one)
Threaded holes to hold assorted clamps.
Platform Size 16" × 14"
Working Chamber D × W × H = 16" × 18.5" × 16"
Overall Dimension D × W × H = 22.5" × 33.5" × 24"
Shaking Orbit 12.5 mm OR 25 mm (customized orbit available on request)
Speed 500 RPM @ 12.5 mm orbital stroke
400 RPM @ 25 mm orbital stroke
Control System Microprocessor-based control system or HMI PLC with data logging facility (optional)
Temp. Range 20°C below ambient to 60°C (Minimum temperature 5°C)
Temp. Accuracy ± 0.2°C or better
Temp. Uniformity ± 1°C or better
RPM Accuracy ± 2 RPM or better
Alarm Temperature overshoot & undershoot alarm provided.
Mechanism Heavy-duty, long-lasting mechanism with both orbital & linear motion.
Illumination Inspection lamp provided. Illumination unit for photosynthesis can be provided (optional)
Power Required 230V, 50Hz, single phase, 15 amp stabilized.

Contact Us

Manufacturers Of Laboratory Rotary Shakers, Orbital Shakers, Incubator Shakers, Stackable Shaker, Laboratory Illuminated Shakers, Lab Oven, BOD Incubator, Stability Test Chamber.Floor Mounted Shakers, Table Mounted Shakers, Shaking Incubators, Platform Shakers, Benchtop Shaker Incubator